Penetrating keratoplasty :graft rejection | |
An old case of Penetrating keratoplasty with all sutures has been removed. Patients c/o of blurring of vision. The lower 3/4 of graft is thickened as seen in section of the slit lamp. Also notice part of cornea seen against light coming from the iris (retro illumination), that part is s not transparent with kps. A case of endothelial graft rejection | |
Abdelshafik, Adel, Prof. Dr. med., Ain Shams University, Cairo, Egypt | |
Z94.7, H18.9 | |
Cornea -> Surgical Procedures and Postoperative Findings -> Complications | |
Cornea , keratoplasty, complications, graft rejetion | |
8605 |